The product digitalization is nowadays part of almost any product development, so that the digitalization of air insulated high voltage disconnectors and earthing switches will be introduced. The motivation by consequences for the product installation and maintenance are given and necessary considerations for the different available and required operation methods of the product are included. Possible data sources within the product are categorized and applied use cases are explained. The possible use cases are covering the switching position, counted operations including forecasting and the monitoring of the anti-condensation heating, as simple use cases. Those are complemented by highly beneficial use cases, as the more known and expectable motor current monitoring and the overcurrent allowance, which is driven by the indirect proportionality of a temperature rise at one current value to a temperature rise of a second current value and the resulting quotient of both currents to the same potency, as per IEC TR 62271-306. The overcurrent allowance use case may not be as expectable, since the IEC reference is not directly related to disconnector and earthing switches, and therefore its underlying calculation methodology is explained and elaborated in detail with boundary conditions and its visualization by a case example. The calculated temperature rise factor is introduced and different safety margins are highlighted. Further use cases with information about realization complexity and potential benefits are complementing the product digitalization possibilities and opportunities. Finally, the applied use cases are illustrated by an executed example of a digitalized center break disconnector.

Published in American Journal of Science, Engineering and Technology (Volume 7, Issue 3)
DOI 10.11648/j.ajset.20220703.13
Page(s) 77-86
Creative Commons

This is an Open Access article, distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution and reproduction in any medium or format, provided the original work is properly cited.

Copyright

Copyright © The Author(s), 2022. Published by Science Publishing Group

Keywords

Disconnector, Current Path, Digitalization, Use Cases, Switching Position, Motor Current, Overcurrent, Temperature Rise

References
[1] M. Rohmann, D. Schraeder, „Swicthing Capability of Air-Insulated High Voltage Disconnectors by Active Add-On Features”, ASTESJ Volume 6, Issue 1, Page No 43-48, 2021, ISSN 2415-6698.
[2] M. Rohmann, S. Challa, G. Kurra, S. Mogatala and D. Schraeder, "Switching Capability of Air Insulated High Voltage Disconnectors," 2019 International Conference on High Voltage Engineering and Technology (ICHVET), 2019, pp. 1-4, doi: 10.1109/ICHVET.2019.8724315.
[3] IEC TR 62271-306, Guide to IEC 62271-100, IEC 62271-1 and other IEC standards related to alternating current circuit-breakers, Edition 1.1, 2018.
[4] IEC 62271-102, High-voltage switchgear and controlgear – Part 102: Alternating current disconnectors and earthing switches, Edition 2.0, 2018.
[5] IEC 62271-1, High-voltage switchgear and controlgear – Part 1: Common specifications for alternating current switchgear and controlgear, Edition 2.0, 2017.
[6] IEC 17025, General requirements for the competence of testing and calibration laboratories, 3rd Edition, 2017.
[7] CIGRE Technical Brochure No. 511: Final Report of the 2004 – 2007 International Enquiry on Reliability of High Voltage Equipment, Part 3 – Disconnectors and Earthing Switches, 2012.
[8] Sunil S Rao, “Switchgear Protection and Power Systems (Theory, Practive and Solved Problems)”, Khanna Publishers, 2008.
[9] M. Rohmann, “Analysis of Assembly Times for a Gas-Insulated High Voltage Switchgear on the Level of Components”, M. Sc. Thesis with Siemens AG at FernUniversitaet Hagen, 2008.
[10] E. Kuffel, W. S. Zaengl and J. Kuffel, “High Voltage Engineering Fundamentals”, published by Butterworth-Heinemann, Great Britain, 2000, ISBN 978-0-7506-3634-6.
[11] Helmut Lindner, Dr. Harry Brauer, Prof. Dr. Constants Lehmann, “Pocket Book of Electro-Technics and Electronics”, Fachbuchverlag Leipzig, 1999, ISBN 3-446-21056-3.
[12] Gerd Balzer, Bernhard Boehle, Kurt Haneke, Hans Georg Kaiser, Rolf Pöhlmann, Wolfgang Tettenborn, Gerhard Voß, “Substations”, 9th ed., Cornelsen Verlag Schwann-Giradet Duesseldorf, 1992, ISBN 3-464-48233-2.
Cite This Article
  • APA Style

    Mariusz Rohmann, Dirk Schraeder. (2022). Digitalization of Air Insulated High Voltage Disconnectors and Earthing Switches. American Journal of Science, Engineering and Technology, 7(3), 77-86. https://doi.org/10.11648/j.ajset.20220703.13

    Copy | Download

    ACS Style

    Mariusz Rohmann; Dirk Schraeder. Digitalization of Air Insulated High Voltage Disconnectors and Earthing Switches. Am. J. Sci. Eng. Technol. 2022, 7(3), 77-86. doi: 10.11648/j.ajset.20220703.13

    Copy | Download

    AMA Style

    Mariusz Rohmann, Dirk Schraeder. Digitalization of Air Insulated High Voltage Disconnectors and Earthing Switches. Am J Sci Eng Technol. 2022;7(3):77-86. doi: 10.11648/j.ajset.20220703.13

    Copy | Download

  • @article{10.11648/j.ajset.20220703.13,
      author = {Mariusz Rohmann and Dirk Schraeder},
      title = {Digitalization of Air Insulated High Voltage Disconnectors and Earthing Switches},
      journal = {American Journal of Science, Engineering and Technology},
      volume = {7},
      number = {3},
      pages = {77-86},
      doi = {10.11648/j.ajset.20220703.13},
      url = {https://doi.org/10.11648/j.ajset.20220703.13},
      eprint = {https://article.sciencepublishinggroup.com/pdf/10.11648.j.ajset.20220703.13},
      abstract = {The product digitalization is nowadays part of almost any product development, so that the digitalization of air insulated high voltage disconnectors and earthing switches will be introduced. The motivation by consequences for the product installation and maintenance are given and necessary considerations for the different available and required operation methods of the product are included. Possible data sources within the product are categorized and applied use cases are explained. The possible use cases are covering the switching position, counted operations including forecasting and the monitoring of the anti-condensation heating, as simple use cases. Those are complemented by highly beneficial use cases, as the more known and expectable motor current monitoring and the overcurrent allowance, which is driven by the indirect proportionality of a temperature rise at one current value to a temperature rise of a second current value and the resulting quotient of both currents to the same potency, as per IEC TR 62271-306. The overcurrent allowance use case may not be as expectable, since the IEC reference is not directly related to disconnector and earthing switches, and therefore its underlying calculation methodology is explained and elaborated in detail with boundary conditions and its visualization by a case example. The calculated temperature rise factor is introduced and different safety margins are highlighted. Further use cases with information about realization complexity and potential benefits are complementing the product digitalization possibilities and opportunities. Finally, the applied use cases are illustrated by an executed example of a digitalized center break disconnector.},
     year = {2022}
    }
    

    Copy | Download

  • TY  - JOUR
    T1  - Digitalization of Air Insulated High Voltage Disconnectors and Earthing Switches
    AU  - Mariusz Rohmann
    AU  - Dirk Schraeder
    Y1  - 2022/08/04
    PY  - 2022
    N1  - https://doi.org/10.11648/j.ajset.20220703.13
    DO  - 10.11648/j.ajset.20220703.13
    T2  - American Journal of Science, Engineering and Technology
    JF  - American Journal of Science, Engineering and Technology
    JO  - American Journal of Science, Engineering and Technology
    SP  - 77
    EP  - 86
    PB  - Science Publishing Group
    SN  - 2578-8353
    UR  - https://doi.org/10.11648/j.ajset.20220703.13
    AB  - The product digitalization is nowadays part of almost any product development, so that the digitalization of air insulated high voltage disconnectors and earthing switches will be introduced. The motivation by consequences for the product installation and maintenance are given and necessary considerations for the different available and required operation methods of the product are included. Possible data sources within the product are categorized and applied use cases are explained. The possible use cases are covering the switching position, counted operations including forecasting and the monitoring of the anti-condensation heating, as simple use cases. Those are complemented by highly beneficial use cases, as the more known and expectable motor current monitoring and the overcurrent allowance, which is driven by the indirect proportionality of a temperature rise at one current value to a temperature rise of a second current value and the resulting quotient of both currents to the same potency, as per IEC TR 62271-306. The overcurrent allowance use case may not be as expectable, since the IEC reference is not directly related to disconnector and earthing switches, and therefore its underlying calculation methodology is explained and elaborated in detail with boundary conditions and its visualization by a case example. The calculated temperature rise factor is introduced and different safety margins are highlighted. Further use cases with information about realization complexity and potential benefits are complementing the product digitalization possibilities and opportunities. Finally, the applied use cases are illustrated by an executed example of a digitalized center break disconnector.
    VL  - 7
    IS  - 3
    ER  - 

    Copy | Download

Author Information
  • Research and Development Queretaro, Siemens Energy S. de R. L. de C. V., Queretaro, Mexico

  • Research and Development Mechanical Engineering and Testing, Siemens Energy Global GmbH & Co. KG, Berlin, Germany

  • Sections