A tertiary neonatal intensive care unit (NICU) in China has carried out a study investigating the safety and accuracy of intracavitary electrocardiogram (IC-ECG) guidance in PICC tip placement in preterm infants. From October 2015 to September 2018, IC-ECG-guidance was applied in 327 preterm infants in our NICU. The positioning of the PICC was performed under ECG-guidance and subsequently assessed by chest X-ray. The frequency of correct ECG-guided PICC-placement in one single attempt, premature infants gender, weight, weeks’ gestational age at PICC insertion was recorded. 327preterm infants(207 male and 120 female)were included in the study with a gestation of 31.3 weeks (25.3 to 36.8) and birth weight of 1498 g (600 to 2560). 327 PICCs tip placement was guided with IC-ECG, all concordant with chest X-ray. 313 (95.7%) were correctly positioned, 228 (72.3%) were correctly positioned on the first attempt, 5 were incorrectly identified to have a short line and 9 were malpositioned. The most commonly punctured vein was the basilic vein (n=228), followed by the superficial temporal vein (n = 31), the axillary vein (n = 25). For 3 years IC-ECG method has proved to be a simple, safe, quick method to assess the correct positioning of the PICC in preterm infants. This is a reliable technique, performing real-time manipulation without any complications.
Published in | American Journal of Nursing Science (Volume 8, Issue 4) |
DOI | 10.11648/j.ajns.20190804.13 |
Page(s) | 142-144 |
Creative Commons |
This is an Open Access article, distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution and reproduction in any medium or format, provided the original work is properly cited. |
Copyright |
Copyright © The Author(s), 2019. Published by Science Publishing Group |
Intracavitary ECG, Malposition, PICC, Tip Placement, Premature Infants, Radiography
[1] | Pittiruti M, Bertollo D, Briglia E, et al. The intracavitary ECG method for positioning the tip of central venous catheters: results of an Italian multicenter study [J]. Journal of Vascular Access, 2012, 13 (3): 357-365. |
[2] | Oliver G, Jones M. ECG-based PICC tip verification system: an evaluation 5 years on. [J]. British Journal of Nursing, 2016, 25 (19): S4-S10. |
[3] | Walker G, Chan R J, Alexandrou E, et al. Effectiveness of electrocardiographic guidance in CVAD tip placement [J]. British Journal of Nursing, 2015, 24 (14): S4, S6, S8. |
[4] | Perin G, Scarpa M G. Defining central venous line position in children: tips for the tip [J]. Journal of Vascular Access, 2016, 16 (2): 0-0. |
[5] | Rossetti F, Pittiruti M, Lamperti M, et al. The intracavitary ECG method for positioning the tip of central venous access devices in pediatric patients: results of an Italian multicenter study. [J]. Journal of Vascular Access, 2014, 13 (3): 137-143. |
[6] | Neubauer A P. Central venous placement of silastic catheters by a recording of an intravascular ECG--a prospective study in 50 premature infants weighing less than 1000 g. [J]. Klinische Padiatrie, 1991, 203 (3): 146-148. |
[7] | Neubauer A P. Percutaneous central i.v. access in the neonate: experience with 535 silastic catheters [J]. Acta Paediatrica, 2010, 84 (7): 756-760. |
[8] | Weber F, Buitenhuis M, Lequin M H. Determination of the optimal length of insertion of central venous catheters in pediatric patients by endovascular ECG [J]. Minerva Anestesiologica, 2013, 79 (4): 379-84. |
[9] | Perin G. PICC placement in the neonate [J]. New England Journal of Medicine, 2014, 370 (22): 2153. |
[10] | Sharpe E, Kuhn L, Ratz D, et al. Neonatal Peripherally Inserted Central Catheter Practices and Providers: Results From the Neonatal PICC1 Survey [J]. Advances in Neonatal Care, 2016, 17: 1. |
[11] | Gemma O, Matt J. ECG or X-ray as the 'gold standard' for establishing PICC-tip location? [J]. British Journal of Nursing, 2014, 19: 10-6. |
[12] | Baldinelli F, Capozzoli G, Pedrazzoli R, Marzano N. Evaluation of the correct position of peripherally inserted central catheters: anatomical landmark vs. electrocardiographic technique [J]. Journal of Vascular Access, 2015; 16 (5): 394–398. |
[13] | Capasso A, Mastroianni R, Passariello A, et al. The intracavitary electrocardiography method for positioning the tip of epicutaneous cava catheter in neonates: Pilot study [J]. The Journal of Vascular Access, 2018:112972981876129. |
[14] | Zhou L, Xu H, Liang J, et al. Effectiveness of Intracavitary Electrocardiogram Guidance in Peripherally Inserted Central Catheter Tip Placement in Neonates [J]. Journal of Perinatal & Neonatal Nursing, 2017, 31 (4). |
[15] | Zhou L, Xu H, Xu M, et al. An accuracy study of the Intracavitary Electrocardiogram (IC-ECG) guided peripherally inserted central catheter tip placement among neonates [J]. Open Med, 2017, 12 (1): 125-130. |
APA Style
Lilan He, Weiju Chen, Meng Zhang, Na Lin, Wenyan Yang. (2019). Outcome of Intracavitary Electrocardiogram Guidance in PICC Tip Placement in Preterm Infants: A Single-center Experience of 327 Cases. American Journal of Nursing Science, 8(4), 142-144. https://doi.org/10.11648/j.ajns.20190804.13
ACS Style
Lilan He; Weiju Chen; Meng Zhang; Na Lin; Wenyan Yang. Outcome of Intracavitary Electrocardiogram Guidance in PICC Tip Placement in Preterm Infants: A Single-center Experience of 327 Cases. Am. J. Nurs. Sci. 2019, 8(4), 142-144. doi: 10.11648/j.ajns.20190804.13
AMA Style
Lilan He, Weiju Chen, Meng Zhang, Na Lin, Wenyan Yang. Outcome of Intracavitary Electrocardiogram Guidance in PICC Tip Placement in Preterm Infants: A Single-center Experience of 327 Cases. Am J Nurs Sci. 2019;8(4):142-144. doi: 10.11648/j.ajns.20190804.13
@article{10.11648/j.ajns.20190804.13, author = {Lilan He and Weiju Chen and Meng Zhang and Na Lin and Wenyan Yang}, title = {Outcome of Intracavitary Electrocardiogram Guidance in PICC Tip Placement in Preterm Infants: A Single-center Experience of 327 Cases}, journal = {American Journal of Nursing Science}, volume = {8}, number = {4}, pages = {142-144}, doi = {10.11648/j.ajns.20190804.13}, url = {https://doi.org/10.11648/j.ajns.20190804.13}, eprint = {https://article.sciencepublishinggroup.com/pdf/10.11648.j.ajns.20190804.13}, abstract = {A tertiary neonatal intensive care unit (NICU) in China has carried out a study investigating the safety and accuracy of intracavitary electrocardiogram (IC-ECG) guidance in PICC tip placement in preterm infants. From October 2015 to September 2018, IC-ECG-guidance was applied in 327 preterm infants in our NICU. The positioning of the PICC was performed under ECG-guidance and subsequently assessed by chest X-ray. The frequency of correct ECG-guided PICC-placement in one single attempt, premature infants gender, weight, weeks’ gestational age at PICC insertion was recorded. 327preterm infants(207 male and 120 female)were included in the study with a gestation of 31.3 weeks (25.3 to 36.8) and birth weight of 1498 g (600 to 2560). 327 PICCs tip placement was guided with IC-ECG, all concordant with chest X-ray. 313 (95.7%) were correctly positioned, 228 (72.3%) were correctly positioned on the first attempt, 5 were incorrectly identified to have a short line and 9 were malpositioned. The most commonly punctured vein was the basilic vein (n=228), followed by the superficial temporal vein (n = 31), the axillary vein (n = 25). For 3 years IC-ECG method has proved to be a simple, safe, quick method to assess the correct positioning of the PICC in preterm infants. This is a reliable technique, performing real-time manipulation without any complications.}, year = {2019} }
TY - JOUR T1 - Outcome of Intracavitary Electrocardiogram Guidance in PICC Tip Placement in Preterm Infants: A Single-center Experience of 327 Cases AU - Lilan He AU - Weiju Chen AU - Meng Zhang AU - Na Lin AU - Wenyan Yang Y1 - 2019/06/04 PY - 2019 N1 - https://doi.org/10.11648/j.ajns.20190804.13 DO - 10.11648/j.ajns.20190804.13 T2 - American Journal of Nursing Science JF - American Journal of Nursing Science JO - American Journal of Nursing Science SP - 142 EP - 144 PB - Science Publishing Group SN - 2328-5753 UR - https://doi.org/10.11648/j.ajns.20190804.13 AB - A tertiary neonatal intensive care unit (NICU) in China has carried out a study investigating the safety and accuracy of intracavitary electrocardiogram (IC-ECG) guidance in PICC tip placement in preterm infants. From October 2015 to September 2018, IC-ECG-guidance was applied in 327 preterm infants in our NICU. The positioning of the PICC was performed under ECG-guidance and subsequently assessed by chest X-ray. The frequency of correct ECG-guided PICC-placement in one single attempt, premature infants gender, weight, weeks’ gestational age at PICC insertion was recorded. 327preterm infants(207 male and 120 female)were included in the study with a gestation of 31.3 weeks (25.3 to 36.8) and birth weight of 1498 g (600 to 2560). 327 PICCs tip placement was guided with IC-ECG, all concordant with chest X-ray. 313 (95.7%) were correctly positioned, 228 (72.3%) were correctly positioned on the first attempt, 5 were incorrectly identified to have a short line and 9 were malpositioned. The most commonly punctured vein was the basilic vein (n=228), followed by the superficial temporal vein (n = 31), the axillary vein (n = 25). For 3 years IC-ECG method has proved to be a simple, safe, quick method to assess the correct positioning of the PICC in preterm infants. This is a reliable technique, performing real-time manipulation without any complications. VL - 8 IS - 4 ER -