The surface topography characteristics of the working surface of the gas valve cover of a gas meter can be used to quantitatively evaluate the sealing performance of the gas valve. A set of surface topography measurement devices based on line laser triangulation was fabricated to study the relationship between the flatness of the valve cover and valve tightness. In the experiment, several qualified and unqualified valve covers were selected for the measurement, and the original data of the three-dimensional topography of the valve cover surface were obtained; the data were tilted and corrected to obtain the flatness error of the valve cover surface. The experimental results showed that when the sampling data point interval is optimized, the flatness error can be used to distinguish the air valve cover sealing characteristics. When the X-axis sampling interval is 0.1 mm and the Y-axis sampling interval is 0.02 mm, the air valve cover rotates at 0°, and the flatness error threshold for distinguishing whether the air valve is qualified or not is approximately 0.1105 mm. Tightness testing method is verified, which provides an important foundation to realize higher accuracy measurement of gas meter.
Published in | American Journal of Optics and Photonics (Volume 8, Issue 4) |
DOI | 10.11648/j.ajop.20200804.11 |
Page(s) | 74-80 |
Creative Commons |
This is an Open Access article, distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution and reproduction in any medium or format, provided the original work is properly cited. |
Copyright |
Copyright © The Author(s), 2020. Published by Science Publishing Group |
Flatness Error, Line Laser Triangulation Method, Air Valve Cover Tightness, Surface Topography Detection
[1] | Ting, C. (2018) Laser scanning gas meter valve air tightness tester. Mechanical Design 35 (S1), 162-165. |
[2] | Li, Y.-H. and Zhang, W.-W (2013) Research on verification device of household diaphragm gas meter. Automation Instrumentation 34 (02), 72-75. |
[3] | Jin, Z.-J., Mao, Q.-M. (2011) Development of a gas tightness tester for membrane gas meters. Journal of China Institute of Metrology 22(01), 15-19. |
[4] | Zhang, L.-Y., Shen, X.-Y., Cui, T., Ye, S.-X., and Li, D.-S. (2016) A new type of diaphragm gas meter valve sealing tester. Lubrication Engineering 41(01), 115-119. |
[5] | Liu, Y., Liu, Y.-H, Wu, M.-X, Ting, C., and Shen, X.-Y (2020) Research on the roughness and morphology characteristics of the valve fitting surface of a gas meter. China Test 46 (08), 143-148. |
[6] | Šarbort, M. et al. (2019) Comparison of three focus sensors for optical topography measurement of rough surfaces. Optics Express 27 (23), 33459. |
[7] | Guo, M.-J. et al. (2020) Embedded laser wheelset wear detection online. Journal of Henan Normal University (Natural Science Edition) 48 (05), 43-48. |
[8] | Bagnall, D. K., Jones, E. J., Balke, S., Morgan, C. L., and McBratney, A. B. (2020) An in situ method for quantifying tillage effects on soil structure using multistripe laser triangulation. Geoderma 380, 114642. |
[9] | Pavlovčič, U., Rak, G., Hočevar, M., and Jezeršek, M. (2020) Ranging of turbulent water surfaces using a laser triangulation principle in a laboratory environment. Journal of Hydraulic Engineering 146 (8), 04020052 |
[10] | Sioma, A. (2020) Automated control of surface defects on ceramic tiles using 3D image analysis. Materials 13 (5), 1250. |
[11] | Li, X.-Z., Shi, Z.-Y., Chen, H.-F., and Lin, J.-C. (2017) Research status and trend of aero-engine blade profile measurement technology. Journal of Beijing University of Technology 43 (04), 557-565. |
[12] | Zhao, H.-J., Shi, S.-G., Gu, X.-F., Jia, G.-R., and Xu, L.-B. (2017) Integrated system for auto-registered hyperspectral and 3D structure measurement at the point scale. Remote Sensing 9 (6), 512. |
[13] | Ting, C., Shen, X.-Y., Hu, J.-C., Li, D.-S., and Li, J.-F. (2013) Research on the gas tightness detection of gas meter valves by laser triangulation method. Optoelectronic Engineering 40 (07), 71-76. |
[14] | Wang, Y., Shu, X.-D., Tian, D.-Y., Wei, Y.-L., and Zhu, Y. (2017) The influence of process parameters on the flange straightness of thin-walled tapered spinning parts. Mechanical Science and Technology 36 (07), 1068-1072. |
[15] | Liu, K.-M., Tao, W., Chen, X., Li, Z., and Zhao, H. (2020) Laser triangulation method for glass thickness with adaptive displacement change. Chinese Laser 47 (01), 155-162. |
APA Style
Yuan Liu, Yuchen Dai, Xiaoyan Shen, Dongsheng Li. (2020). Sealing Test of Gas Valve Cover of Gas Meter Based on Line Laser Triangulation Method. American Journal of Optics and Photonics, 8(4), 74-80. https://doi.org/10.11648/j.ajop.20200804.11
ACS Style
Yuan Liu; Yuchen Dai; Xiaoyan Shen; Dongsheng Li. Sealing Test of Gas Valve Cover of Gas Meter Based on Line Laser Triangulation Method. Am. J. Opt. Photonics 2020, 8(4), 74-80. doi: 10.11648/j.ajop.20200804.11
AMA Style
Yuan Liu, Yuchen Dai, Xiaoyan Shen, Dongsheng Li. Sealing Test of Gas Valve Cover of Gas Meter Based on Line Laser Triangulation Method. Am J Opt Photonics. 2020;8(4):74-80. doi: 10.11648/j.ajop.20200804.11
@article{10.11648/j.ajop.20200804.11, author = {Yuan Liu and Yuchen Dai and Xiaoyan Shen and Dongsheng Li}, title = {Sealing Test of Gas Valve Cover of Gas Meter Based on Line Laser Triangulation Method}, journal = {American Journal of Optics and Photonics}, volume = {8}, number = {4}, pages = {74-80}, doi = {10.11648/j.ajop.20200804.11}, url = {https://doi.org/10.11648/j.ajop.20200804.11}, eprint = {https://article.sciencepublishinggroup.com/pdf/10.11648.j.ajop.20200804.11}, abstract = {The surface topography characteristics of the working surface of the gas valve cover of a gas meter can be used to quantitatively evaluate the sealing performance of the gas valve. A set of surface topography measurement devices based on line laser triangulation was fabricated to study the relationship between the flatness of the valve cover and valve tightness. In the experiment, several qualified and unqualified valve covers were selected for the measurement, and the original data of the three-dimensional topography of the valve cover surface were obtained; the data were tilted and corrected to obtain the flatness error of the valve cover surface. The experimental results showed that when the sampling data point interval is optimized, the flatness error can be used to distinguish the air valve cover sealing characteristics. When the X-axis sampling interval is 0.1 mm and the Y-axis sampling interval is 0.02 mm, the air valve cover rotates at 0°, and the flatness error threshold for distinguishing whether the air valve is qualified or not is approximately 0.1105 mm. Tightness testing method is verified, which provides an important foundation to realize higher accuracy measurement of gas meter.}, year = {2020} }
TY - JOUR T1 - Sealing Test of Gas Valve Cover of Gas Meter Based on Line Laser Triangulation Method AU - Yuan Liu AU - Yuchen Dai AU - Xiaoyan Shen AU - Dongsheng Li Y1 - 2020/11/27 PY - 2020 N1 - https://doi.org/10.11648/j.ajop.20200804.11 DO - 10.11648/j.ajop.20200804.11 T2 - American Journal of Optics and Photonics JF - American Journal of Optics and Photonics JO - American Journal of Optics and Photonics SP - 74 EP - 80 PB - Science Publishing Group SN - 2330-8494 UR - https://doi.org/10.11648/j.ajop.20200804.11 AB - The surface topography characteristics of the working surface of the gas valve cover of a gas meter can be used to quantitatively evaluate the sealing performance of the gas valve. A set of surface topography measurement devices based on line laser triangulation was fabricated to study the relationship between the flatness of the valve cover and valve tightness. In the experiment, several qualified and unqualified valve covers were selected for the measurement, and the original data of the three-dimensional topography of the valve cover surface were obtained; the data were tilted and corrected to obtain the flatness error of the valve cover surface. The experimental results showed that when the sampling data point interval is optimized, the flatness error can be used to distinguish the air valve cover sealing characteristics. When the X-axis sampling interval is 0.1 mm and the Y-axis sampling interval is 0.02 mm, the air valve cover rotates at 0°, and the flatness error threshold for distinguishing whether the air valve is qualified or not is approximately 0.1105 mm. Tightness testing method is verified, which provides an important foundation to realize higher accuracy measurement of gas meter. VL - 8 IS - 4 ER -